Home > Products > Additive dosing pump for FAP

Additive dosing pump for FAP

Additive dosing pump for FAP

 

In 1995, based of its know-how in microdosing, Gurtner has developed a micro precision pump, a key element of the module used for the regeneration of particulate filter

With this pump, Gurtner demonstrates its ability to meet the most stringent requirements in terms of accuracy and repeatability.

Pompe Doseuse Gurtner


Specifications

 Displacement

 6,5 mm³ ±5%

 Operating frequency

 Maxi 20Hz

 Mains voltage

 11 to 16 Volts

 Inlet pressure

 -40 mbar to +100 mbar

 Max. outlet pressure

 800 mbar

 Minimum permissible viscosity of the fluid used

 1 mPa.s

 Maximum permissible viscosity of the fluid used

 400 mPa.s

 Temperature

 -30°C to +80°C

 Resistance

 20 ohms ±1

 Inductance

 40 mH under 1 kHz

 Dimensions

 Lg 71mm / Ø 32mm

 Weight

 150 g

 

 

 

GURTNER | 40, rue de la libération CS 60129 - 25302 PONTARLIER Cedex